Part 1 of 3 · Series: Hygienic Electrical Design for Food & Beverage Plants
Food and beverage processing facilities are designed and built with the protection of consumer health as a primary priority. Hygienic zoning, washdown procedures, and sanitation programs all serve that priority by keeping pathogens away from product before it reaches a consumer.
FDA, USDA, and Food Safety Modernization Act (FSMA) requirements set the regulatory framework for food safety.1,2 Meeting these requirements goes beyond cleaning practices and includes initiatives such as plant design and material selection.
Many facilities zone their plants by contamination risk, restricting how hazards, people, and materials move from low-risk areas toward exposed product.3 For electrical infrastructure, a second question matters just as much: what conditions each area creates. Mapping the zones and the conditions they face first, then matching materials and components to them, keeps a facility’s electrical infrastructure aligned with the same sanitation standards the rest of the plant is built around.
Hygienic Zoning
Not every part of a food processing facility carries the same contamination risk or faces the same environmental conditions and cleaning requirements. A commonly used classification, which FDA presents as one way to characterize a plant, divides facilities into four zones by how close each surface is to food, ranked from highest risk (Zone 1) to lowest risk (Zone 4).4,5 Layouts and zone naming conventions can vary, but the examples below show where each zone typically appears.
Zone 1: Direct Food-Contact Surfaces (Highest Risk)
Includes any surface that directly touches food, such as conveyor belts, slicing blades, knives, mixer bowls, rollers, worker hands, and packaging chutes.
Zone 2: Adjacent/Indirect Food-Contact Surfaces (High Risk)
Includes surfaces and equipment close to food where debris or condensate could splash or transfer into Zone 1, such as machine outer frames, structural supports, control panels, pumps, and chill units.
Zone 3: Processing Environment / Non-Product Areas (Lower Risk)
Includes non-food-contact surfaces within the same production and processing area, such as floors, floor drains, walls, ceilings, pipes, and trash cans.
Zone 4: Remote / General Areas (Lowest Risk)
Includes areas well away from exposed food or processing, such as offices, hallways, locker rooms, cafeterias, loading docks, and maintenance shops.6
The closer the surfaces are to a food product, the stricter the cleaning procedures and, thus, the harsher the conditions. Additionally, the lower the zone number, the more closely its surfaces will be checked and monitored for pathogens. Part 3 of this series (coming soon) covers environmental monitoring in more depth.
Conduit Systems
Often overlooked, conduit systems, powering equipment throughout a food and beverage facility, can pass through various zones. A conduit drop to a motor on a ready-to-eat line would generally be treated as a Zone 2 surface and would face high-pressure washdown. A wall-mounted run in the same room would generally be Zone 3. FDA recommends sampling Zones 1 and 2 most often, since contamination there poses the greatest risk to product.4,6 Areas closest to exposed product also tend to see the most intensive washdowns, so conduit there needs to hold up to repeated cleaning and stay cleanable where it is checked most often.
Conditions Across the Plant
Environmental conditions also vary across the plant. Some areas stay dry, while others see hot water, high-pressure spray, and harsh cleaning chemicals every day. Industry sanitary design guidance calls for washdown-rated motors and power components, and enclosed, gasketed lighting in washdown areas.7 Layouts vary from plant to plant, but the conditions below show the range a conduit system might face and where conduit commonly runs in each.
High-pressure washdown areas: Frequent high-pressure washdowns with hot water and harsh cleaning chemicals, including caustic or acidic solutions. National Electrical Manufacturers Association (NEMA) enclosure ratings describe the protection electrical equipment needs in these conditions: Type 4 covers hose-directed water, and Type 4X adds protection against corrosion.8
Areas: meat and poultry cutting rooms and ready-to-eat processing lines.
Conduit runs: drops to motors, sensors, and instruments on the processing line itself, directly in the path of washdown spray and chemicals.
Routine washdown areas: Frequent cleaning with water and chemicals keeps surfaces wet, and moisture fosters the growth and transfer of bacteria such as Listeria.4
Areas: cooking and kettle areas, filling rooms, and raw material handling.
Conduit runs: power to mixers, pumps, kettles, and filling equipment, along walls or dropping to equipment from overhead.
Splash areas: Product can incidentally contact machines, floors, or other surfaces.
Areas: secondary packaging lines and corridors next to processing rooms.
Conduit runs: feeds to case packers, labelers, and conveyors, plus wall-mounted runs to control panels.
Dry areas: No direct food contact and minimal cleaning.
Areas: packaged-goods warehouses, dry ingredient storage, and mechanical rooms.
Conduit runs: power to lighting, HVAC equipment, and general building circuits.
Choosing the Right System for the Conditions
The most reliable approach to material selection and facility planning is to match the conduit system to the conditions it will live in rather than defaulting to a single spec across the whole plant.
Stainless Steel
Stainless steel is a family of iron alloys containing at least 10.5 percent chromium.9 The chromium forms a thin oxide layer on the surface that protects the metal underneath and re-forms on its own when exposed to oxygen, so its corrosion resistance doesn’t depend on a coating that can chip or wear away.10 That is why stainless steel holds up to hot water, steam, and repeated exposure to caustic and acidic cleaners.
Grades differ in how they balance cost and corrosion resistance. Dry and splash areas can typically be served well by Type 304 stainless steel. Routine and high-pressure washdown areas, where caustic washdown, chloride-based sanitizers, or standing moisture are part of daily operations, are where Type 316 is most often specified.
Other Conduit Materials
Galvanized steel, aluminum, and PVC are less suited to washdown than stainless steel. They still show up in older installations and in dry, low-risk areas where washdown exposure is minimal, but each carries its own tradeoffs once it moves into a washdown area. Zinc galvanizing and aluminum are both attacked by the caustic cleaners common in washdown, and PVC can soften and deform under repeated hot-water washdowns.
304 vs. 316: Why Molybdenum Matters
Type 304 stainless steel, made with roughly 18 percent chromium and 8 percent nickel (often called “18-8” stainless), is the standard general-purpose grade used throughout food and beverage plants and performs reliably in dry and splash areas. Type 316 stainless steel starts from a similar base but adds roughly 2 to 3 percent molybdenum, an alloying element that measurably improves resistance to pitting caused by chlorides, the salts and chloride-based sanitizers common in routine and high-pressure washdown areas.11
Metallurgists quantify that difference with the Pitting Resistance Equivalent Number, or PREN, calculated as %Cr + (3.3 × %Mo) + (16 × %N).12 When typical mill compositions are run through this formula, Type 304 generally lands in the high teens, while Type 316’s molybdenum content pushes it into the mid-20s. This formula provides a way to illustrate why 316 is the grade most often specified for washdown areas, where the chemistry is most demanding, while 304 remains a capable, economical choice in dry and splash areas.
For a more detailed comparison, see What Is the Difference Between 304 and 316 Stainless Steel?
Start With the Conditions
Conduit selection in a food and beverage plant starts with where each run sits. A drop to a motor on a ready-to-eat line faces the same hot water, high-pressure spray, and harsh cleaning chemicals as the equipment it feeds, while a run through dry ingredient storage faces little of that. Mapping every run to the conditions it will face, and knowing which monitoring zone it falls in, gives a plant a clear basis for each material and grade decision before the conduit is installed.
Part 2 of this series (coming soon) looks at the washdown cycle itself: the step-by-step cleaning process that washdown areas go through, and the conditions it creates for every surface, conduit included.
To compare Type 304 and Type 316 stainless steel conduit and fittings for the conditions in a specific facility, or for pricing, availability, and ordering, contact your Gibson Stainless representative or distributor.
Frequently Asked Questions
Click Question to See the Answer
What grade of stainless steel is best for food and beverage conduit?
Type 304 stainless steel is a reliable, economical choice for dry and splash areas with limited washdown exposure. Type 316 stainless steel, which adds molybdenum for better resistance to chloride-based cleaning chemicals and salts, is typically specified for routine and high-pressure washdown areas.
What conditions does conduit face in a food processing facility?
Conditions range from dry areas with no food contact and minimal cleaning to high-pressure washdown areas, where exposed product, hot water, and caustic chemicals meet during frequent cleaning. The harsher the conditions, the more corrosion resistance a conduit system needs, so equipment and infrastructure are specified differently depending on where they sit.
How do washdown conditions relate to environmental monitoring zones?
Washdown conditions describe how harsh an area is, including its moisture, cleaning frequency, and chemical exposure, and guide material and equipment selection. Environmental monitoring zones classify surfaces by how close they are to food, from Zone 1 (food-contact surfaces) to Zone 4 (areas outside production), and guide where and how often a plant tests for pathogens. Every surface has both, and areas nearest exposed product usually face the harshest washdowns and the most frequent testing.
Technical References
This article draws on 12 sources, including:
View all 12 references
- U.S. Food and Drug Administration. Food Safety Modernization Act (FSMA).
- U.S. Department of Agriculture, Food Safety and Inspection Service.
- Grassmann, Duane. Hygienic Zoning in Food Manufacturing Factories. Food Safety Magazine, October 17, 2019.
- U.S. Food and Drug Administration. Control of Listeria monocytogenes in Ready-To-Eat Foods: Guidance for Industry. Draft guidance, January 2017.
- Erwin, Cecelia, Robert Williams, and Laura K. Strawn. Introduction to Environmental Monitoring Programs. Virginia Cooperative Extension, Virginia Tech, FST-290NP, reviewed November 2023.
- Gupta, Priyanka, and Achyut Adhikari. Novel Approaches to Environmental Monitoring and Control of Listeria monocytogenes in Food Production Facilities. Foods, 2022.
- Meat Institute and Meat Foundation. Facility Design Principles: Checklist. Arlington, VA, 2015.
- National Electrical Manufacturers Association (NEMA). Enclosures for Electrical Equipment (1,000 Volts Maximum), ANSI/NEMA EN 10250-2026.
- Specialty Steel Industry of North America (SSINA). Alloying Elements.
- worldstainless. Corrosion Properties.
- ASTM International. ASTM A240/A240M-26: Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications.
- Specialty Steel Industry of North America (SSINA). Pitting and Crevice Corrosion.